What will the ALEX HX10 pump unit offer you?
The ALEX HX10 pump unit is designed for small solar thermal installations with a nominal collector area of up to 12 m2 (e.g., 5 KS2100F TLP AC collectors). The high-efficiency circulating pump used allows the stringent requirements of the ErP Directive for maximum electricity consumption to be met. The ALEX HX10 pump unit, from the design stage to its production, is developed at Hewalex on the basis of many years of in-house experience, but above all on the basis of the practical experience of contractors and users of solar thermal installations.
Maximum heat yield at minimum cost
The latest generation of electronically speed-controlled circulation pumps have several times lower electricity consumption than older pumps operating at constant speed. The ALEX HX10 pump unit includes a circulating pump whose operation can be controlled according to the latest control standards (iPWM signal, iPWM2). This allows the use of advanced algorithms to manage the operation of solar thermal systems, based on constant measurements of temperature and flow in the operating circuit. The energy efficiency of the entire solar thermal system is the highest of all heat sources. For every 100 W of heat generated, 1-2 W of electricity is usually sufficient.
Modular design, assembly functionality
The compact dimensions allow the pump unit to be installed in a small space, and the modular design makes installation work easier and less time-consuming. It is also possible to choose to connect the solar circuit to the left or right of the pump unit, or bilaterally. This provides the freedom to choose where to install the pump unit, regardless of the location of the domestic hot water storage tank. Also, the pressure gauge can be freely positioned on the left or right side of the unit, depending on access for convenient reading of the system pressure. A solar thermal system vent installed at the inlet to the hot water storage tank coil is an extremely important addition.
Effective ventilation of installations
The ALEX HX10 pump unit includes an additional T-piece with air vent made according to a new concept. This ensures effective venting of the solar thermal system during initial commissioning and during servicing. Air capture takes place within the coil heat exchanger where, due to the cross-section of the pipes, the glycol flow rate is lowest. The air bubbles here therefore have a greater ability to float upwards towards the vent. The tee is made of brass and has thermal insulation. Venting is at once easily accessible, convenient and quick to carry out.